Oberon TCG100 Series Arc Flash Suits lightweight suits are made from a proprietary blend of arc rated, inherently flame resistant, aramid fibers. Prolonged exposure to high-energy electrical faults can result in severe burns, blast injuries, and fatal arc flash incidents. The TCG100 Series 100 cal Arc Flash Suit is engineered to protect workers operating in the highest-risk electrical environments where standard PPE is not sufficient. This 100 cal suit is ideal for situations where industrial arc flash protection is critical and failure is not an option—Redbank offers compliant, high-performance electrical safety programs.

Key Features & Performance Benefits

  • Certified 100 cal arc flash suit with ATPV rating of 100 cal/cm²

  • Meets and exceeds NFPA 70E PPE Category 5 requirements

  • Constructed from a proprietary blend of inherently flame-resistant aramid fibers

  • Lightweight design to reduce heat stress during extended wear

  • Full-body arc flash protective clothing coverage including hood, coat, and bib overalls

  • Knit cuffs and dual-stage zipper front closure for secure fit and fast donning

  • Adjustable suspenders for comfort across a wide range of body types

  • Reflective day and night striping on arms and legs for enhanced visibility

  • Nearly clear TCG Series hood window providing true colour acuity

  • Anti-fog and anti-scratch coatings for clear vision in demanding environments

  • Optional hood ventilation system and integrated task light

  • Manufactured in the USA to strict quality and safety standards

Designed For a Wide Range of Arc Flash Applications

This arc flash suit for electrical work is designed for professionals exposed to extreme electrical fault energy, including:

  • High-voltage electrical maintenance and shutdowns

  • Utility substations and power generation facilities

  • Switchgear installation, testing, and commissioning

  • Industrial manufacturing plants with high fault current risks

  • Mining, oil and gas, and heavy infrastructure sites

  • Data centres and critical power environments

  • Electrical contractors performing live work under permit

For organisations requiring dependable arc flash protective clothing in Australia, this suit delivers maximum protection without compromising visibility, mobility, or compliance.

Technical Specifications

  • Arc Rating (ATPV): 100 cal/cm²

  • PPE Category: 5

  • Material: Inherently flame-resistant aramid fibre blend

  • Suit Components Included:

               TCG Arc Flash Hood with shield and hard hat
               Arc-rated coat
               Arc-rated bib overalls

  • Hood Window: Near-clear, anti-fog and anti-scratch coated

  • Closure System: Dual-stage zipper front

  • Cuffs: Knit

  • Visibility: Reflective striping on arms and legs

  • Colour: Black

  • Sizes Available: Small to 5XL

  • Optional Accessories: Hood ventilation system and light

  • Gloves: Sold separately

  • Country of Manufacture: USA

  • Compliance: NFPA 70E

Frequently Asked Questions

What Is a 100 Cal Arc Flash Suit Used For?
A 100 cal arc flash suit is used in environments where the incident energy exceeds lower PPE categories. It is required for extreme electrical hazards such as high-voltage switchgear, substations, and industrial power systems where severe arc flash exposure is possible.

Is This Considered Extreme Arc Flash Protection Clothing?
Yes. With an ATPV rating of 100 cal/cm², this suit is classified as an extreme arc flash protection suit and is intended for the highest-risk electrical work scenarios.

Is This Arc Flash Protective Clothing Suitable for Use in Australia?
Absolutely. This arc flash protective clothing in Australia is commonly supplied to utilities, mining operations, and industrial facilities. It meets internationally recognised NFPA 70E standards and aligns with Australian workplace safety expectations.

Does the Hood Provide Clear Visibility During Work?
Yes. The TCG hood features a nearly clear window with true colour acuity, allowing accurate identification of wiring, components, and instruments while maintaining full arc flash protection.

Who Typically Purchases This Level of Arc Flash PPE?
This suit is commonly selected by electrical contractors, utilities, and safety managers sourcing equipment from a specialist arc flash PPE supplier in Australia for high-risk, permitted electrical tasks.

Is This Suit Comfortable for Extended Wear?
Despite its high protection rating, the lightweight aramid construction, adjustable suspenders, and optional ventilation system help reduce heat stress and improve comfort during long-duration work.

Does This Arc Flash Suit Include Gloves?
No. Gloves are not included and should be selected separately to match the required arc rating and task-specific hand protection needs.